REFRIGERATION R22 PHASE OUT

If your current refrigeration or air conditioning system is running on refrigerant gas R22 Sensible Air Solutions can help with surveying, de-commissioning and replacement of your system.

(Click + the sign to open and close each topic, below)

After 1 January 2010 no more virgin refrigerant R22 can be used in existing systems.

After 2015 no more recycled refrigerant R22 can be used in existing systems.

If you have had an R22 air conditioning system recently installed the phase out dates should be a cause for your concern. Your system should only require more refrigerant should a leak or major repair be required and this can be effected within current legislation until 2015.

Existing units using R-22 will not continue to be serviced with R-22 from 1st of January 2010. This means new refrigerant cannot be bought to fill this system only existing, stockpiled or reclaimed. Additionally, the new substitute refrigerants cannot be used without making some changes to system components. This means that service technicians who repair leaks to the system will continue to charge R-22 into the system as part of that repair.

While consumers should be aware that prices of R-22 may increase as supplies dwindle over the next 20 or 30 years, EPA believes that consumers are not likely to be subjected to major price increases within a short time period. Although there is no guarantee that service costs of R-22 will not increase, the lengthy phase out period for R-22 means that market conditions should not be greatly affected by the volatility and resulting refrigerant price hikes that have characterized the phase out of R-12, the refrigerant used in automotive air-conditioning systems and commercial chillers.

As R-22 is gradually phased out, non-ozone-depleting alternative refrigerants are being introduced. Under the Clean Air Act, EPA reviews alternatives to ozone-depleting substances like R-22 in order to evaluate their effects on human health and the environment. EPA has reviewed several of these alternatives to R-22 and has compiled a list of substitutes <http://www.epa.gov/Ozone/snap/refrigerants/lists/homeac.html> that EPA has determined are acceptable. One of these substitutes is R-410A, a blend of hydro fluorocarbons (HFCs), substances that do not contribute to depletion of the ozone layer, but, like R-22, contribute to global warming. R-410A is manufactured and sold under various trade names, including GENETRON AZ-20®, SUVA 410A®, and Puron®. Additional refrigerants on the list of acceptable substitutes include R-134a and R-407C. EPA will continue to review new non-ozone-depleting refrigerants as they are developed.

The transition away from ozone-depleting R-22 to systems that rely on replacement refrigerants like R-410A has required redesign of heat pump and air conditioning systems. New systems incorporate compressors and othercomponents specifically designed for use with specific replacement refrigerants. With these significant product and production process changes, testing and training must also change. Consumers should be aware that dealers of systems that use substitute refrigerants should be schooled in installation and service techniques required for use of that substitute refrigerant.

Another important thing user can do for the environment is to purchase a highly energy-efficient system. Energy-efficient systems result in cost savings for the user. Today’s best air conditioners use much less energy to produce the same amount of cooling as air conditioners made in the mid-1970s. Even if your air conditioner is only 10 years old, you may save significantly on your cooling energy costs by replacing it with a newer, more efficient model. Products with EPA’s Energy Star® label can save homeowners 10% to 40% on their heating and cooling bills every year. These products are made by most major manufacturers and have the same features as standard products but also incorporate energy saving technology. Both R-22 and R-410A systems may have the Energy Star® label. Equipment that displays the Energy Star® label must have a minimum seasonal energy efficiency ratio (COP). The higher the cop specification, the more efficient the equipment.

You should consider energy efficiency, along with performance, reliability and cost, in making your decision. And don’t forget that when purchasing a new system, you can also speed the transition away from ozone-depleting R-22 by choosing a system that uses ozone-friendly refrigerants.

From 01/07/1995 – HCFC’s will be banned except as solvents, as refrigerants, for the production of rigid insulating foams and integral skin foams in safety applications, in laboratory uses, including research and development, as feedstock in the manufacture of other chemicals and as a carrier gas for sterilisation substances in closed systems.

From 01/01/1996 – HCFC’s will be banned in the following uses: in equipment produced after 31/12/95 as: refrigerants in non-confined direct evaporation systems; refrigerants in domestic refrigerators and freezers; in motor vehicle, tractor and off road vehicle or trailer air conditioning and inroad public transport air conditioning.

From 01/01/1998 – HCFC use will be banned in equipment produced after 31/12/97 for rail public transport air conditioning.

From 01/01/2000 – HCFC use will be banned in equipment produced after 31/12/99 for use as refrigerants in public distribution and cold stores and warehouses and as refrigerants for equipment of 150kW and over shaft input.

From 01/01/2001 – HCFC’s are banned in all other refrigeration and air conditioning equipment produced after 31/12/2000, with the exception of fixed a/c equipment, with a cooling capacity of less than 100kW where use shall be prohibited from 01/01/2004 and of reversible air conditioning / heat pump systems where the use of HCFC’s shall be prohibited from 01/01/2004 in allequipment produced after 31/12/2003.

01/01/2010 – The use of virgin HCFC’s shall be prohibited in the maintenance and servicing of refrigeration and air conditioning equipment existing at that date.

From 01/01/2015 – The use of recycled HCFC’s will be prohibited in the maintenance and servicing of refrigeration and air conditioning equipment existing at that date.

R134A is a single hydrofluorocarbon or HFC compound. It has no chlorine content, no ozone depletion potential, and only a modest global warming potential. – ODP = 0, GWP = 1300

R407C is a ternary blend of hydrofluorocarbon or HFC compounds, comprising 23% of R32, 25% of R125 and 52% of R134a. It has no chlorine content, no ozone depletion potential, and only a modest direct global warming potential. – ODP = 0, GWP = 1610

R410A is a binary blend of hydrofluorocarbon or HFC compounds, comprising 50% of R32 and 50% of R125) it has no chlorine content, no ozone depletion potential, and only a modest global warming potential. – ODP = 0, GWP 1890

R417A is the zero ODP replacement for R22 suitable for new equipment and as a drop-in replacement for existing systems.

There are currently no restrictions on equipment or use of the following refrigerants: R134A, R407C, R410A, and R417A.

Contact Sensible Air Solutions for your R22 phase out consultation with one of our engineers now to discuss your options.

Air Conditioning Manufacturers Logos

GET A QUOTE

CALL 0161 614 0702 FOR A FREE QUOTE, SITE SURVEY OR MORE INFORMATION.

Sensible Air Solutions offer a complete service to help you decide upon the appropriate air conditioning system for your individual requirements.

We can advise you as to which system to use, and how to install it. We appreciate that everyone will have particular needs, and our free site survey is there to help you get exactly what you are looking for.

More details are on our ‘Choosing the Right Air Conditioning System for Your Needs’ page

Modern air conditioning is now available in a huge range of styles, sizes, capability and functionality.

Typical systems are

  • Wall Mounted
  • Floor or Ceiling Mounted
  • Ceiling Mounted Cassette
  • Ducted
  • Multi-Split Systems
  • VRF Variable Refrigerant Flow System
  • Rooftop Packaged Unit
  • Heat Recovery systems

Each have their own advantages, and this is why we strongly recommend you take advantage of our free consultation so we can discuss with you what might be the best option for your circumstances, and your budget!

More information about the above systems can be found here

Air Conditioning Systems – What Are Your Options?

We specialise in the design, installation, service & maintenance of all air conditioning systems. With over 20 years’ experience in the industry SAS has grown and maintained an excellent reputation for a reliable , quality and cost effective service throughout the North West and surrounding areas.

We can supply and install all kinds of different types of air conditioning systems. We don’t employ pushy salesmen, only hands on engineers who can offer experienced professional advice.

We offer a free no obligation site survey where you will incline the best options available to start your budget at the right price.

To get started, you have several options –

  1. Request a Free Site Survey.
  2. Get a Quote.
  3. Ask for Advice to begin with.

We are here to help, and nothing is too much trouble.

If you want to ask anything just get in touch!

Sensible Air Solutions can offer service/maintenance and breakdown packages to suit your requirements.

From one off annual visits to regular monthly visits we can service/maintain all types of air conditioning equipment in all types of environments from residential through to industrial. Our engineers are fully qualified to industry standard and our flexibility allows us to work around your business hours. Under EU F-Gas Regulations it is a legal requirement for you to ensure that your air conditioning is inspected regularly by qualified engineers.

We can also provide our customers with a 24 hour, 365 days a year maintenance cover with optional 24 hour emergency call out.

This is for applications such as catering and server/communications rooms where temperature is critical and down time has to be kept to a minimum.

Call 0161 614 0702 , or email for a quote, information, or a free site survey...